Home › Trane › Trane Furnace › Trane Furnace Error Codes List: Every Code Explained

Trane Furnace Error Codes List: Every Code Explained

Trane Furnace display showing full error code list — FixCode Guide error code graphic

Every Trane furnace error code we could verify against Trane's own documentation — what it means, what usually causes it, and the first fix to try — in one table. Codes differ between model series, so treat your model's tech sheet as the final word.

Safety first. Work safe: power off at the plug or breaker before panels come off, taps closed before hoses come off, and no bypassing of safety devices — ever. Never bypass limit, rollout, pressure or flame-safety devices to force heat. Gas smell, scorch marks or a CO alarm means stop and call a licensed HVAC technician (gas utility for a gas smell).

How to read and retrieve error codes on Trane furnaces

Trane boards provide the fault history through the LED pattern and, on communicating models, through the thermostat's installer menu, which lists stored alert codes (the alphanumeric family). The fault chart on the blower door is the authority for your unit — Trane changed flash-pattern assignments between generations, and charts copied between websites frequently mix them up.

The complete Trane furnace error code list

CodeMeaningMost likely causeFirst fix
2 FlashesSystem lockout; ignition retries or recycles exceededRepeated failed ignition or flame loss, from gas supply, ignitor, flame sensor or pressure switch problemsConfirm the thermostat calls for heat and gas supply to the home is on; do not keep resetting, call a licensed HVAC technician
3 FlashesPressure switch fault — the pressure switch did not close (or the inducer/vent proof failed) on Trane furnaces with LED blink diagnostics.Blocked vent/intakeClear vents; clean the condensate path; replace bad tubing.
4 FlashesOpen temperature limit circuit; the furnace overheated and shut the burners downClogged filter, blocked registers or returns, failing blower, or an open limit switchReplace the filter and open all registers and returns; repeat trips need a licensed HVAC technician
5 FlashesFlame sensed when no flame should be present — Trane's chart wording (UC-series installer's manual and the verified chart): '5 Flashes: Flame sensed when no flame should be present.' The flame sensor is reporting a flame at a time when the gas valve is not energised and no flame may exist.Leaking gas valveOwner's complete fix list for this code is two items: furnace off, and a licensed HVAC technician booked. Everything below is the technician's work, described so you can recognise a proper diagnosis when you see one.
6 Flashes115 volt AC power reversed, ignitor (triac) fault, poor grounding, or system voltage too lowReversed line polarity, missing or poor equipment ground, low supply voltage, or a failed ignitor output on the controlDo not operate on suspect wiring; polarity, grounding and control checks are licensed HVAC technician or electrician work
7 FlashesGas valve circuit error — Trane's chart wording is exactly that: '7 Flashes: Gas valve circuit error.' The integrated control has detected a fault in the electrical circuit between itself and the gas valve: the wiring, the valve's coil, or the control's own valve output.Shorted gas valve wiringOwner's scope ends quickly on this code, by design: confirm the gas supply is on, seat an obviously disturbed valve connector with power off, and try the single documented power reset. Everything after that is licensed-technician measurement and repair.
8 FlashesLow flame sense signalCoated flame sensor, poor unit ground, or a weak burner flame from gas pressure problemsFlame sensor cleaning and gas pressure checks are licensed HVAC technician work
9 FlashesOpen inducer limit switch on *UX2/KIT-chart boards; older UC/XB-chart boards use 9 flashes for the ignitor circuit checkTripped inducer limit from inducer overheating, or on older boards an open ignitor circuit or excess neutral-to-common voltageTurn the furnace off and let it cool; inducer limit and ignitor circuit work is licensed HVAC technician work
10 FlashesInducer communication errorFailed communication between the integrated control and the variable-speed inducer motor, or a damaged inducer harnessPower-cycle once at the furnace switch; inducer and control diagnosis is licensed HVAC technician work
CONTINUOUS ONSolid red LED: internal gas valve (GV) error or low thermostat (TH) voltage on *UX2/KIT-chart boards; older UC charts mark solid red as replace the IFCInternal control or gas valve circuit failure, or low 24-volt thermostat-circuit voltageTry one power reset at the furnace switch; a persistent solid red LED needs a licensed HVAC technician
E0Internal failure on A801X-family controls; the same internal-failure family shown as E01 on S-series controlsFailed integrated furnace control electronicsTry one power reset at the furnace switch; control replacement is licensed HVAC technician work
E01Loss of the IRQ or other internal control failuresInternal integrated control fault or corrupted control operationTry one power reset at the furnace switch; a persistent E01 is control board work for a licensed HVAC technician
E2.1Retry exceeded; flame was never established during the ignition retriesNo gas flow, a failed ignitor, or a flame sensor that never proved flameConfirm gas supply to the home is on and the thermostat calls for heat; ignition diagnosis is licensed HVAC technician work
E2.2Recycles exceeded; flame was established then lost repeatedly, or the first-stage pressure switch opened ten timesInterrupted gas supply, coated flame sensor, weak flame, or a pressure switch dropping out during operationClear vent and intake terminations and check the condensate drain; persistent recycles need a licensed HVAC technician
E2.3First-stage gas valve not energized when it should be, ten times within one call for heatControl not sending 24 volts to the low-stage gas valve, a loose gas valve plug, or an internal control relay faultGas valve voltage and control diagnosis is licensed HVAC technician work
E3.1Shorted (stuck closed) pressure switch, first stagePressure switch contacts stuck closed, or wind pressure holding the switch closed at the vent terminationCheck the vent termination is clear; switch testing is licensed HVAC technician work
E3.2Open pressure switch, first stage; draft was not provenBlocked vent or intake, clogged condensate drain, damaged switch hose, or a weak inducerClear vent and intake terminations and check the condensate drain; then a licensed HVAC technician
E3.3Shorted (stuck closed) pressure switch, second stage (two-stage models)Second-stage pressure switch contacts stuck closed, or shorted switch wiringCheck the vent termination is clear; switch testing is licensed HVAC technician work
E3.4Open pressure switch, second stage; high-stage draft was not proven (two-stage models)Vent or intake restriction at high inducer speed, condensate backup, hose fault, or a weak inducerClear vent and intake terminations and check the condensate drain; then a licensed HVAC technician
E04Open thermal limit, rollout switch, or reverse airflow switchOverheating from a clogged filter or blocked airflow, flame rollout, or a failed switch in the series limit circuitReplace the filter and open all registers and returns; do not reset a rollout repeatedly, call a licensed HVAC technician
E05Flame detected when it should not be presentLeaking gas valve keeping a flame alive, a shorted flame sense wire, or a grounded flame sensorTurn the furnace off; gas valve and flame sense faults need a licensed HVAC technician immediately
E6.1Voltage reversed polarity at the furnace supplyHot and neutral line wires reversed at the furnace or junction boxDo not operate on reversed polarity; correction is licensed HVAC technician or electrician work
E6.2Bad grounding at the furnaceMissing or poor equipment ground, or a loose burner or control ground connectionGrounding correction is licensed HVAC technician or electrician work
E6.3Igniter circuit fault: the igniter relay fails or the igniter is openCracked or burned-out igniter, open igniter wiring, or a failed control igniter relayIgniter and control diagnosis is licensed HVAC technician work; do not handle the igniter element
E7.1First-stage gas valve (MVL) is energized when it should be offStuck gas valve relay on the control, or shorted gas valve wiring holding the valve onShut off gas and power to the furnace; call a licensed HVAC technician immediately
E08Flame current is low, but still strong enough to allow operationCoated flame sensor, poor sensor position in the flame, or a weak flame from gas pressure problemsFlame sensor cleaning and flame current measurement are licensed HVAC technician work
E09Not a Trane-published furnace code — no Trane support page, installer guide or service document found defines "E09" for a Trane furnace. Trane's documented residential furnace languages are LED blink codes and worded thermostat alerts on communicating systems, so this page explains how to get E09 decoded honestly instead of inventing a meaning for it.A model-specific display code with a dealer-only decodeThere is no verified fix for E09, because there is no verified meaning — anyone who quotes you a part against 'E09' without your model's chart is selling the guess this page exists to warn about.
E11Gas valve fault group: a gas valve not energized when it should be, or a gas valve relay stuck closedFailed control gas valve relay, open or shorted valve wiring, or a failed gas valveGas valve and control work is licensed HVAC technician work; do not keep resetting
E12Open fuse on the integrated furnace controlA short in the 24-volt thermostat or component wiring blowing the board fuseCheck thermostat wiring for visible damage; fuse replacement and short tracing are licensed HVAC technician work
Ht1Status display, not a fault: first-stage heating is runningNormal operation on a first-stage call for heat from the thermostatNo fix is needed if the home is heating; a fault would appear as an E code on the same display
Ht2Status display, not a fault: second-stage heating is runningNormal operation on a second-stage call for heat; a single-stage thermostat jumpered W1-W2 shows Ht2 at all timesNo fix is needed if the home is heating; a fault would appear as an E code on the same display
IdLStatus display, not a fault: the furnace is idleNo call for heat, cooling or fan from the thermostatSet the thermostat to heat and raise the setpoint if heat is wanted; otherwise no action is needed
SOLID RED WITH SOLID GREENContinuous reset, caused by a blown fuse or internal errorBlown low-voltage fuse on the control, a short in 24-volt wiring, or an internal control failureNote any recent thermostat work for the technician; fuse and short tracing is licensed HVAC technician work
A code that is not in this table? Manufacturers add and retire codes between model years, and some displays abbreviate two-part codes. If your code is missing, note the full display exactly as shown (photograph it), check the tech sheet stored inside the machine, and search this site by the symptom — the fault family is usually identifiable from what the machine was doing when the code appeared.

How to reset / clear error codes on Trane furnaces

Trane furnaces report faults as red-LED flash patterns on the control board (count the flashes between pauses) on non-communicating models, and as alphanumeric codes on communicating/XV models. Soft lockouts retry automatically; hard lockouts clear by fixing the cause and cycling power at the furnace switch. The board stores recent faults — on many models the LED keeps the last fault flash pattern available until the next successful cycle overwrites it.

How to diagnose any Trane furnace code

Work the problem in this order — and stop at any point where gas, combustion or mains wiring is involved, because those belong to a licensed HVAC technician: (1) record the code exactly: count LED flashes slowly, twice, or photograph the alphanumeric display; (2) check the free things homeowners legitimately own: the thermostat is calling for heat, the furnace power switch and breaker are on, the filter is not clogged solid (a starved furnace overheats and locks out on limit codes), all vents and the return are open, and the condensate drain is not blocked on condensing models; (3) reset once — at the power switch, off for 30 seconds — then watch a full call for heat from the beginning: inducer, ignition, flame, blower, in that order; where the sequence stops is the fault family the code names; (4) a code that returns immediately is an active fault — do not keep resetting a lockout, especially any flame or limit code; (5) everything inside the burner compartment — flame sensor cleaning is the one grey area many manuals allow owners, but gas valves, burners, heat exchangers and control boards are professional work. If you smell gas at any point, leave and call the gas utility, not a helpline.

Flash counts on older boards, E-codes on communicating furnaces

Trane furnaces report faults two ways depending on generation. The integrated furnace control on most models flashes a red LED in counted patterns, read against the fault chart printed in the installation manual and on the unit — that chart, for your exact model, is the authority. Trane's communicating and modulating furnaces (the S-series and XV generation) instead show alphanumeric E-codes on a display and store a fault history. The table below covers both dialects and keys each entry the way Trane displays it, because a "4 flashes" fault and an E-code with a similar number are unrelated reports.

Lockouts are the furnace protecting itself, not a second fault

After repeated failed attempts at the same step — ignition above all — a Trane control stops trying and locks out for a period rather than cycling forever against a fault that could overheat the furnace or flood the burners with unburned gas. A lockout is evidence, not damage: it tells you the same step failed repeatedly. Reset once, at the power switch, and watch one full call for heat from the start — inducer, pressure proof, ignition, flame, blower — because where the sequence stops is the fault family. A code that returns immediately is an active fault; do not keep resetting it, and leave everything inside the burner compartment to a licensed HVAC technician.

Blink codes, display codes and lockouts

Two generations of fault reporting live side by side on modern furnaces. Older and simpler boards report through a single LED: a repeating count of flashes, read slowly against the chart printed inside the blower door — that chart, for your exact model, outranks any list on the internet, including this one. Newer communicating furnaces show alphanumeric codes (the E-series in the table above) and store a fault history a technician can scroll. Both generations share the lockout idea: after a set number of failed attempts at the same step — ignition is the classic — the board stops trying for a period (often an hour, or until power is cycled) instead of cycling forever against a fault that could overheat or flood the burners with unburned gas. A furnace in lockout is not broken by the lockout itself; it is a furnace that has already failed the same step repeatedly and is waiting for someone to find out why.

Furnace codes are also seasonal in a way washer codes are not. The first cold snap produces a wave of ignition and flame codes from furnaces that sat idle all summer — oxidised flame sensors, spider-nested burners, pressure-switch hoses holding condensate from the cooling season. Deep-winter adds frozen condensate lines on high-efficiency models and intake/exhaust terminations blocked by snow or ice, which present as pressure-switch codes. A code that appears once, on the coldest night of the year, and never again has often met its cause already; a code that appears every cycle, in any weather, is a component asking to be tested.

The most searched Trane furnace codes, in detail

E09 — Not a Trane-published furnace code

This is the page we publish when a code cannot be verified, and the reasoning is worth showing. Trane's own consumer guidance on furnace codes (its blinking-light troubleshooting page) teaches homeowners to count LED flashes and write codes down exactly, and warns against DIY furnace repair — but it never lists an E09. Trane's published ignition diagnostics (Trane's support knowledge base, covering its ignition controller boards) define the furnace fault language as flash counts: 2 flashes for system lockout, 3 for a pressure switch problem, 4 for an open high limit, 5 for flame sensed with the gas valve off, 6 for an open rollout, and so on. On Trane's communicating systems, alerts surface on the thermostat in worded or formally numbered formats (the ERR and CFG families on ComfortLink controls), again not as a bare E09. And when Trane Home's own support is asked about codes, its published answer is blunt: Trane Home Support cannot decipher error codes, and questions about their meanings go to your HVAC dealer. Against that silence, third-party websites confidently define E09 — and disagree with each other, some calling it a pressure-switch fault, others a communication or sensor fault. Mutually contradictory definitions with no manufacturer document behind any of them are the fingerprint of a code being guessed at. The honest summary: some Trane-family boards do show character displays, and an E09 seen on one can only be decoded by that model's own rating-plate documentation or door chart — not by the internet's consensus.

Most likely cause: A model-specific display code with a dealer-only decode — The most likely truth behind most E09 reports: display-equipped Trane platforms can generate codes that Trane documents in installer and dealer literature rather than in anything published for homeowners. The code is real to the board that posted it — it simply has no public Trane definition, which is a documentation gap, not permission to borrow one from another brand or site.

First check: Photograph the display showing E09 and write the characters down exactly, including anything before or after them — the full string, not the memorable part of it.

If it keeps coming back: An undefined code 'keeps coming back' for the simplest of reasons: the condition behind it was never identified, so it was never fixed. Every E09 that survives a power cycle should escalate the documentation hunt — exact string, model number, door chart, dealer decode — rather than another round of resets or a part bought against a guessed meaning.

3 Flashes — Pressure switch fault

On Trane's blink-code furnaces, 3 flashes is the pressure-switch family: the inducer ran but the switch didn't prove draft (on many Trane charts, 3 flashes covers pressure switch stuck open/closed variants — the chart inside the blower door is the authority for your exact model). The diagnosis is the universal pressure-switch chain: vent/intake blockage (snow and nests lead), condensate trap/drain on condensing models, the switch's tubing (cracked or water-filled), inducer strength, and the switch itself last. Trane's own wording for this code is worth having exactly, because it names three different problems under one flash count. In Trane's published ignition-controller diagnostics, the entry reads: "3 Flashes — Pressure switch problem detected (no vent air flow, bad CBM, closed at an initial call for heat). Auto reset." Read the brackets as a branch list. Branch one, no vent air flow: the inducer runs but cannot move enough air — or pull enough vacuum — for the switch to prove the vent path. Branch two, the switch was already closed at the initial call for heat: the board checks the switch before the inducer starts, finds proof it has not earned yet, and aborts the sequence immediately rather than firing on a switch it cannot trust. Branch three is the control itself (the board Trane abbreviates as the CBM in that table). All three report identically — three flashes, no ignition — which is why the observed sequence matters so much: a code that appears before the inducer even starts is branch two or three talking, while a code that arrives after the inducer has run points at the airflow branch. The same Trane table closes with the behaviour owners ask about most: this fault is an auto reset, so the board will try again on the next call once the condition clears, with no manual reset ritual required or published.

Most likely cause: Blocked vent/intake — Snow, ice, nests — the winter classic.

First check: SAFETY: never jumper a pressure switch to 'test' heating — it proves exhaust can leave.

If it keeps coming back: Cold-snap recurrence = termination icing or a freezing condensate line; rainy-day recurrence = vent water/sag. The returns of this code tend to follow the weather and the water. Inducer and vent proofs that pass in mild weather fail on the coldest nights, when a frost-narrowed termination or a sluggish condensate drain steals the last of the vacuum margin; condensate branches return whenever the trap or tube re-fills faster than it drains. A 3-flash pattern that clusters at night or in cold snaps is telling you the margin — not the switch — is the disease, and it is why a technician who only swaps the switch often gets the same callback Trane's branch list was written to prevent.

5 Flashes — Flame sensed when no flame should be present

A furnace control spends its whole life asking one question in two directions: during a burn, 'is the flame really there?' — and at every other moment, 'is the flame really gone?' Five flashes is the second question failing. The control is receiving a flame-proving signal (the flame sensor works by flame rectification: a real flame conducts a tiny DC current between the sensor rod and the burner, and the control reads that current as proof) while the gas valve is de-energised — at standby, before ignition, or after a cycle that should have ended clean. Only three physical stories produce that signal, and Trane's verified chart names them: a leaking or stuck gas valve keeping a real flame alive on gas it should be holding back; a lingering burner flame that has not gone out when it should; or a fault in the flame sensing circuit itself, where the signal is false — Trane's display-generation wording for the same fault (code E05 on S-series/A801X controls) lists a shorted flame sense wire or a grounded flame sensor alongside the leaking valve. The control's response is not negotiable and not a glitch to be cleared: flame out of sequence is among the most serious reports a furnace can make, because each branch is bad in a different way — uncommanded gas burning, or a safeguard that can no longer be believed. If the sensor lies in the 'flame present' direction today, nothing guarantees its honesty in the other direction tomorrow. That is why the verified fix for 5 flashes begins with turning the furnace off, and why this page will not offer a reset-and-run path: the furnace stays off until a technician has established which of the three stories is true. Note the contrast with 8 flashes (low flame sense signal): that is a weak-but-honest signal during a legitimate burn — a cleaning-and-measurement job. Five flashes is a signal at a forbidden time, and forbidden beats weak in every safety hierarchy.

Most likely cause: Leaking gas valve — Trane's lead cause: the valve passes gas with its solenoid de-energised, so a flame — even a small, lazy one at one burner port — persists or re-establishes after the cycle should have ended. The flame the sensor reports is real; it is the valve's shutoff that is fictional. This branch is a gas-safety fault, not a controls nuisance.

First check: SAFETY OVERRIDES EVERY OTHER STEP: if you smell gas, turn the furnace off, shut off gas at the furnace's manual valve if you know where it is, leave the house if the smell is strong, and call your gas utility or a licensed HVAC technician. Never attempt to bypass, disconnect or defeat the flame sensor to get heat — the sensor is the safeguard this code is about.

If it keeps coming back: Five flashes returning after a gas valve replacement, with the new valve proven tight, walks the diagnosis into the sensing chain — wiring shorting intermittently under vibration or heat, a sensor grounding only when hot, or the control's sense circuit drifting. Returns that cluster at the end of cycles keep pointing at flame behaviour (burners, carryover, residual gas); returns at cold power-up keep pointing at the signal. The timing pattern is the diagnosis — record it rather than resetting it away.

7 Flashes — Gas valve circuit error

Where 5 flashes reports what the flame sensor sees, 7 flashes reports what the control knows about its own wiring. The integrated furnace control continuously supervises the gas valve circuit — the output it switches, the harness that carries it, and the valve's solenoid coil at the end of it — and 7 flashes is that supervision failing: the circuit is shorted, open, or drawing or answering in a way the control cannot accept. Trane's verified chart gives the three suspects without ornament: shorted or open gas valve wiring, a failed gas valve coil, or a control board gas valve output fault. Trane's display generation splits this one IFC bucket into the branches the LED chart cannot express, and the split is worth knowing because it shows what 'circuit error' contains: E2.3 is the first-stage gas valve not energised when it should be (ten times within one call for heat); E7.1 is its dangerous mirror — the gas valve energised when it should be off, from a stuck relay or shorted wiring holding the valve on; and E11 is the gas valve fault group that gathers both directions. The LED generation wraps all of that into 7 flashes, so the code by itself does not say whether your furnace cannot open its valve (the common, merely cold outcome: the sequence runs, the igniter may glow, and ignition never happens because the valve is never truly powered) or cannot be trusted to keep it closed (the rare, dangerous outcome the E7.1 branch describes). Either way the control refuses to run a heating cycle on a valve circuit it cannot vouch for, and either way the diagnosis is measurement, not observation: coil resistance, voltage at the valve during the ignition window, and continuity of the harness separate the three suspects in an order no amount of power-cycling can imitate. Note what 7 flashes is not: a gas supply problem. A closed manual valve or an empty street main starves a healthy circuit and produces ignition failure and eventually a 2-flash lockout — the valve was commanded and answered, the flame simply never came. Seven flashes means the command path itself failed its check.

Most likely cause: Shorted gas valve wiring — Trane's first suspect: the harness between control and valve shorted — chafed insulation against the cabinet, a pinched run, or heat-damaged conductors — so the control's valve output sees a load or a path it should not. A short in this circuit is also the branch that can hold a valve energised, which is why the code is treated as a safety report and not a mere no-heat nuisance.

First check: SAFETY: this is a gas valve circuit fault. If you smell gas, furnace off, gas off at the manual valve if you know it, and call your utility or a technician. Never jumper the gas valve, never apply power to the valve manually to test it, and never bypass the control to force a heating cycle — those are precisely the acts this code exists to prevent.

If it keeps coming back: A 7-flash that returns weeks after a repair, especially intermittently, is usually the harness branch maturing: a chafe that only shorts when the cabinet vibrates under the inducer, or a connector pin that loses contact as it heats. Intermittence is itself the clue — log when it faults (cold start, mid-cycle, after other work nearby) rather than resetting the evidence away. Returns immediately after a valve or control replacement mean the unproven half of the pair: the part that was not changed was the guilty one, and the measurement sequence, done fully this time, settles it.

Less common and model-specific codes

Search data shows owners also meet these codes on Trane furnaces: 7P1, E2, E24, E3, E4, E6, Fixes, HE1, HE2. They are not part of the core code list Trane publishes for most models — several are series-specific, abbreviated display readings, or codes carried over from a sister platform — so we do not publish meanings for them rather than guess. Treat them by symptom: note what the machine was doing when the code appeared (filling, draining, heating, spinning), run one full power cycle (5 minutes off), and if the code returns, match the symptom to the closest documented family in the table above and check the tech sheet stored inside your machine for the model-specific definition.

Deep-dive guides for the most searched codes

Trane Furnace 3 Flashes: What the Blinking Light Means & FixesTrane Furnace E09 Error Code: Meaning, Causes & FixTrane Furnace 5 Flashes: What the Blinking Light Means & FixesTrane Furnace 7 Flashes: What the Blinking Light Means & Fixes